#891/3 INSTALLATION/OPERATION/SERVICE MANUAL 4.
INSTALLATION
1. An identification tag is permanently mounted
on the cabinet.
2. Plug the unit into a properly grounded
receptacle ONLY. Arcing will occur when
connecting or disconnecting the unit unless
all controls are in the OFF position.
3. Position the unit so the cord is easily accessible
in case of any emergencies. If necessary, a
proper receptacle or outlet configuration, as
required for the unit, must be installed by a
licensed electrician in accordance with
applicable, local electrical codes.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in
close vicinity, an equalization-bonding stud is
provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection
against potential difference. The terminal is
marked with the following symbol.
NOTE: The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
Electrical Installation
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be made
in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
NEMA 6-20P
20A-250V PLUG
CEE 7/7
220-230V PLUG
NEMA 6-20P
20A-250V PLUG
CEE
7/7
220-230V
PLUG
ELECTRICAL Model 1018 COMBIMATE
VOLTAGE PHASE CYCLE/HZ AMPS kW CORD & PLUG INCLUDED
at 208 1 50/60 13.2 2.8
at 240 1 50/60 15.4 3.7
at 230 1 50/60 14.7 3.4
NEMA 6-20P
20A - 250V PLUG
CEE
7/7
220-230V PLUG
230 208-240
ELECTRICAL Model 1220 COMBIMATE
VOLTAGE PHASE CYCLE/HZ AMPS kW CORD & PLUG INCLUDED
at 208 1 50/60 14.4 3.0
at 240 1 50/60 16.2 3.9
at 230 1 50/60 14.8 3.4
230 208-240
ELECTRICAL Model 2020 COMBIMATE
VOLTAGE PHASE CYCLE/HZ AMPS kW CORD & PLUG INCLUDED
at 208 1 50/60 14.4 3.0
at 220 1 50/60 15.0 3.4
at 240 1 50/60 16.7 4.0
at 230 1 50/60 15.5 3.5
230 240 - 220 - 208