ELECTRONIC CONTROL ACCURACY
The electronic control is a precise instrument and is
designed to offer trouble-free service. If you suspect
the temperature inside the warming cabinet does not
match the temperature indicated on the digital
display, after stabilizing, follow the instructions
listed below.
1. Check to make certain the unit voltage matches
the power source. A power source less than that
required to operate the unit will result in
inaccurate temperatures.
2. Verify the temperature inside the holding
compartment with a qualify thermal indicator.
A. With the exception of the wire shelves,
completely empty the holding compartment.
B. Make certain the holding cabinet sensor,
located inside the holding compartment at
the left side of the unit, is completely clean.
C. Suspend the thermal indicator in the center
of the holding compartment.
D. Allow the temperature set on the electronic
thermostat to stabilize for a minimum of one
hour before comparing the digital display
with the reading on the thermal indicator.
DO NOT OPEN THE CABINET DOOR(S)
DURING THE TEMPERATURE
STABILIZATION PERIOD.
If the reading on the thermal indicator does not
match the digital display, there may be a problem
with the air sensor. See troubleshooting guide in this
manual, or call the factory service department for
advice.